一般社団法人日本呼吸器学会 公式サイト
日本呼吸器学会英文誌 Respiratory Investigation
日本呼吸器学会誌 増刊号 学術講演会プログラム 抄録集 検索用
日本呼吸器学会誌 増刊号 学術講演会プログラム 抄録集 全文PDF

Abstract

Full Text of PDF Full Text of PDF (324k)
Article in Japanese

Diagnostic Imaging

Three cases of air embolism during CT-guided percutaneous needle lung biopsy

Hiroe Suzukia  Makiko Yomotaa  Kana Hashimotoa  Yasunobu Takakib  Yukio Hosomia 

aDepartment of Thoracic Oncology and Respiratory Medicine, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital
bDepartment of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital

ABSTRACT

Computed tomography (CT)-guided percutaneous needle biopsy is a useful method for the diagnosis of lung lesions. We report herein three cases of air embolism following a CT-guided percutaneous needle biopsy in which the clinical course of air movement and eventual resolution of the embolism were able to be observed. In all three cases, the coronary artery air embolism and renal artery air embolism resolved after 40 to 50 minutes of rest without causing any organ damage. Arterial embolisms associated with a CT-guided percutaneous needle biopsy may self-resolve without organ damage. Whenever an air embolism occurs, knowing its clinical course and the appropriate method of intervention is important.

KEYWORDS

CT-guided percutaneous needle biopsy  Air embolism  Complication 

Received 12 Apr 2020 / Accepted 17 Nov 2020

AJRS, 10(2): 202-205, 2021

Google Scholar